OMRON Automatic Blood Pressure Monitor Standard HEM-7121, providing accurate and comfortable upper arm blood pressure measurement with Enhanced IntelliSense Technology. With Advanced Accuracy, an exclusive OMRON technology, this monitor measures five times more data points for consistent, precise readings.
FEATURES
-
Cuff Wrapping Guide
Guides user to the right cuff wrap by indicating “OK” to ensure an accurate and reliable blood pressure measurement.
-
Body Movement Detection
Prompts user to retake measurement when an error is detected due to body movement
-
Hypertension Indicator
Heartbeat symbol blinks if your systolic or diastolic pressure is outside the standard range (above 135 systolic/85 diastolic mmHg).
-
Irregular Heartbeat Detection
An irregular heartbeat is a heartbeat rhythm that varies by more than 25% from the average heartbeat rhythm detected while the unit is measuring blood pressure.
1. If such an irregular rhythm is detected more than twice during measurement, the irregular heartbeat symbol appears on the display with the measurement result.
2. If the irregular heartbeats cause the measurement to be invalid, no result is shown.
3. If the irregular heartbeat symbol is shown after you have taken a measurement, repeat the measurement.
4. If the symbol continues to appear, we recommend you to consult your healthcare professional.
- Enhanced IntelliSense Technology
The new algorithm enhances measurement accuracy with a standard deviation of less than 4 mmHg. With a press of a button, the enhanced IntelliSense Technology delivers accurate measurements with comfort and ease of use.
The Enhanced IntelliSense™ Monitor inflates the cuff to the ideal level with each use. No adjustments are required by the user to select an inflation level. This is especially convenient for hypertensive users and for people with certain arrhythmia or heart disorders, because their blood pressure is likely to fluctuate.
Advantages of Enhanced IntelliSense Technology
- Fully automatic
- Personalized inflation for maximum comfort
- Quick deflation releases valve for speedy measurement
SPECIFICATION
Cuff Wrapping Guide
Body Movement Detection
Hypertension Indicator
Irregular Heartbeat Detection
Enhanced IntelliSense Technology
INSTRUCTION
Instruction Manual Provided.
WARNINGS
Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter.