Rossmax RA600 Infrared Ear Thermometer has been carefully developed for accurate, safe and fast temperature measurements in the ear. It is a non-invasive ear thermometer using an infrared detector to detect body temperature from the auditory canal for adult and child.
The quality of the infrared ear thermometer has been verified and conforms to the provisions of the EC council directive 93/42/EEC(Medical Device Directive) Annex I essential requirements and applied harmonized standards. EN 12470-5: 2003 Clinical thermometers-Part 5: Performance of infrared ear thermometers (with maximum device.)
This thermometer converts the ear temperature to display its “oral equivalent.” (according to the result of the clinical evaluation). It means measurable and reminds to use a probe cover for measurement.
FEATURES
- Highest accuracy by rotating in 3” Scanning Mode
or 1” measurement - Multiple-Use Plug & Secure Probe Cover
(Clean the Probe Cover with alcohol after every use) - Ear temperature
- Fever Alarm
- 9 memories
- °C / °F switchable
- Backlight
- Auto shut-off
- Low battery indicator
- Self-diagnosis for malfunction
Multiple-Use Plug & Secure Probe Cover
(Clean the Probe Cover with alcohol after every use)
The patented “Plug & Secure” probe covers are very durable, ideal for multiple use and offer an easy and accurate ear temperature measurement. Users can easily assure the probe cover is attached and the appliance is ready to use. The well-designed heat insulation probe can ensure accurate, consistent reading and short interval between each measurement. Clinical validation complies with ASTM 1965-98 and PrEN 12470-5.
DIRECTION
How to use the RA600 Infrared Ear Thermometer
- To achieve accurate readings, make sure a clean Probe Cover is in place before each measurement and the ear canal is clean. a. Install the Probe Cover by clockwise rotating; then fix it. b. Remove the Probe Cover by anti-clockwise rotating; then release it.
- Press the “On/Off/Memory” button, the thermometer is ready for use after the ear icon is flashing, two beeps are sounded, and three dash segments are appeared.
- As the ear canal is slightly curved, you have to pull the ear slight up and backwards before inserting the probe. This is important so that the tip of the Probe Cover can be pointed directly at the eardrum. a. Before measurement, the correct installation of the Probe Cover ensures an accurate measurement. b. Replace with a new Probe Cover after approx. 30 times of use to ensure an accurate reading. c. This thermometer must only be used with Rossmax Probe Covers, other covers can lead to inaccuracy. If running out of Probe Covers, please contact the original seller or distributor for buying new Probe Covers. Do never measure without Probe Cover or with a broken Probe Cover.
- Measuring the ear temperature:
- with 1” measurement: Use the index finger to trigger, by pressing “Start” button, a long beep will be sounded when measurement is done.
- with 3” Scanning Mode: For highest accuracy always use 3” Scanning Mode.
Use the index finger to trigger, press and hold the “Start” button for 3 seconds to take measurement. Gently rotate the probe in the entire ear canal in order to find the highest temperature. Release the “Start” button until hearing a long beep sound and the measurement is completed.
- For the next measurement, ensure that there is no breakage or stains of Probe Cover before each measurement, otherwise replace the Probe Cover with a new one.
- Power off: If left idle for more than 1 minute, device will automatically shut off for extending battery life. Or press “On/Off/Memory” button for at least 3 seconds to turn the device off.
- Fever alarm: When the measuring temperature is higher than 37.5 °C(99.5°F), the reading will flash, the backlight will be enabled, and 4 short beeps will be sounded.
If measuring temperature is higher than 42.2 °C(108°F), the display will show “Hi”, the backlight will be enabled, and 4 short beeps will be sounded.
- It is recommended that you measure 3 times with the same ear within a short period of time. If the 3 consecutive measurements are different, select the highest temperature; or do a 3” Scanning Mode measurement to find highest temperature.
- To avoid the cross contamination risk, please clean the probe and Probe Cover according to “ Clean and Storage” section after each use.
SPECIFICATION
- Batteries
- Instruction Manual
- Probe Cover
- Dimensions: 22.7 x 10.2 x 3 cm
- Weight: 150 Grams
WARNING
This is a home healthcare product only, and it is not intended to serve as a substitute for the advice of a healthcare professional.